top of page

Pricing the Right Not to Take: A Gas Product for Generators Facing Negative Electricity Prices

Nov 20
7 min read
A natural-gas generator stands beside sunlit solar panels at an energy site.

When midday solar output pushes wholesale power prices below zero, a gas-fired generator may ask its supplier for a discount on gas it cannot profitably burn. Rather than reduce the commodity price across all deliveries, a seller can offer a defined gas non-take right: the buyer may reduce specified nominations in agreed intervals, within a capped volume and under clear settlement terms.

This is not a blanket discount or a guaranteed benefit for either party. Its value depends on the generator’s dispatch economics, the seller’s ability to redirect released gas, and the nomination, imbalance and take-or-pay terms at the delivery point.

Why Negative Electricity Prices Reach the Gas Contract

Negative electricity prices can occur when demand is lower than expected, renewable output is abundant and other generation cannot reduce output easily. The European Commission recorded 4,407 negative-price hours across the selected European day-ahead markets it tracked in the second quarter of 2025. Its report also describes how some conventional plants may continue producing at negative prices to avoid costly shutdowns and restarts. The Commission’s Q2 2025 electricity market report provides the market context.

The frequency varies by market area. Germany’s regulator recorded negative wholesale prices in 573 of 8,760 hours in 2025, while the IEA reported that negative prices occurred during about 6% of hours in France, Germany, the Netherlands and Spain. Those figures describe past market conditions, not a forecast for any generator. A power-market price below zero also does not make gas cheaper or determine whether a particular unit should run: fuel and emissions costs, variable operating costs, restart costs, power revenues and other contract payments all matter. Germany’s 2025 electricity market data and the IEA’s review of negative pricing in 2025 show why a contract trigger needs a defined location and interval.

The Commercial Gap Between a Discount and Flexibility

A broad gas discount changes the price of delivered supply, even when the generator only needs relief for certain hours. A non-take right instead defines when the buyer may reduce or release a specified quantity, and who carries the costs or receives any resale value. That distinction matters when a supplier has already scheduled transport, hedged its portfolio or committed the gas elsewhere.

Keep the physical gas obligation separate from any financial hedge or power-market exposure. A hedge may settle even when physical nominations fall, depending on its terms. Nedjma’s overview of gas hedging for industrial buyers covers the broader commodity structures; the issue here is how a contract allocates the cost of not taking gas.

How to Price the Right Not to Take Gas

A seller could negotiate a “solar-hour release strip” as an add-on to an existing gas supply agreement. It would give the generator a limited right to reduce or release gas during specified periods, while leaving the price formula for gas actually delivered intact. Unless counterparties identify a standardized product in their market, they should treat this as a negotiated contract structure, not an established exchange product.

Define the physical right first

Before setting a fee, specify the delivery point, eligible time windows, maximum release volume, notice deadline and whether the buyer may defer gas or cancel it permanently. State whether the released quantity remains subject to take-or-pay, whether it can be made up later, and how minimum-take obligations change. If the buyer still owes for gas it does not receive, the arrangement may not resolve the cost that prompted the request.

The contract should also distinguish a price-triggered release from an ordinary change in plant operation. A generator may reduce output because of maintenance, an outage, a system instruction or a different dispatch decision. Those events should not qualify automatically unless the parties intend them to, and can verify them.

Set value from both sides

For a generator exposed to the relevant wholesale price, the buyer-side value can be assessed from the operating costs and negative-price exposure it avoids, less any lost energy, capacity or ancillary-service revenue, support payments, restart costs and imbalance charges. The calculation must reflect the plant’s actual commercial position. A negative day-ahead price alone does not establish that shutting down is better than running.

The seller’s calculation starts with the margin or portfolio value it gives up, then accounts for hedge adjustments, transport, capacity, balancing and other costs of releasing the gas. Any value recovered by selling that gas elsewhere can reduce the seller’s cost, but only when a suitable outlet is available and the resale proceeds can be established. A guide to gas trading hubs and regional benchmarks is relevant when the alternative outlet is at a different location, where transport and basis differences may affect the result.

Separate availability, exercise and resale

The contract can distinguish the cost of making flexibility available from the settlement for actually using it. The parties can select the components that match their exposures, while avoiding payment twice for the same value.

  • Availability chargeUse this where the seller must reserve portfolio capacity or maintain the ability to release a defined volume. The charge should reflect the agreed availability obligation, not an assumed value for future power prices.

  • Exercise settlementDefine how a confirmed release is paid for or credited, including the quantity, market reference and calculation period. The power-market trigger and the gas settlement index do not have to be the same reference.

  • Resale creditIf the seller resells released gas, the agreement can specify how verified proceeds are shared after agreed incremental costs. It should also state what happens when no compatible buyer, transport path or capacity is available.

Each component needs a clear boundary. A contract that charges a full exercise amount and also passes through the full resale proceeds may compensate one party twice for a single release. Conversely, a credit based on an assumed resale can leave the seller carrying the full downside when the molecule cannot be redirected.

Make the trigger measurable

Specify the bidding zone, market product, delivery interval and data source used to establish an eligible event. The trigger might use a day-ahead price condition, a confirmed dispatch instruction or both. Add a notice process and a verifiable baseline, such as the accepted gas nomination before the release request, so that the released quantity can be calculated from confirmed data.

The trigger should reflect the generator’s actual exposure. Some units may continue producing during negative-price periods because of start-up costs, support arrangements, power hedges or other revenues. A price condition without an availability or dispatch test could therefore activate the gas right when the buyer has no economic reason to use it.

Match power intervals to gas nominations

European day-ahead electricity trading moved to 15-minute intervals for delivery beginning on 1 October 2025. That finer power-market timing does not automatically make physical gas deliveries adjustable every 15 minutes. The SDAC implementation notice confirms the electricity-market change.

Gas nomination and renomination rules depend on the market, point and transport agreement. Under the EU gas balancing code, renomination cycles at interconnection points run hourly, and a flow change generally takes effect two hours after the cycle starts unless the relevant arrangements allow another timing. The EU gas balancing regulation sets out those procedures, while ACER’s overview of gas balancing explains the respective roles of network users and transmission system operators. (eur-lex.europa.eu)

That creates a practical limit: a short power-market signal may arrive too late for a physical gas-flow change. The agreement should therefore align its notice deadline and release block with what the applicable transport rules and delivery arrangements can actually support. Where physical changes cannot follow every power interval, settlement can use a longer agreed block while keeping the underlying trigger and released volume auditable.

What the Seller and Generator Must Put in Place

Before offering or accepting a non-take right, both parties need to check whether the paper option can be delivered operationally. A limited pilot based on verified dispatch and nomination data can expose timing, balancing and settlement issues before a wider contract is agreed.

  • Reconcile plant dataMatch dispatch, power settlement, gas nominations and metered consumption by delivery interval. Separate negative-price events from outages, maintenance and other reasons for lower output.

  • Map the gas outletIdentify where the released volume could be sold, whether transport capacity is available and how location, quality, balancing and title transfer affect the resale calculation.

  • Review local rulesCheck applicable nomination deadlines, delivery terms, imbalance allocation, take-or-pay provisions and any support or contract obligations that could change the generator’s incentive.

  • Build the settlement trailRecord the trigger, notice, confirmed nomination, meter data, release volume and any resale credit. A defined trade lifecycle helps keep the calculation reviewable; Nedjma’s overview of ETRM trade capture and settlement introduces the systems context.

  • Set pilot limitsAgree the eligible periods, maximum volume, approval process and review criteria before the first release. Include a process for disputed data, unavailable outlets and rejected or late nominations.

Questions About Negative Electricity Prices

Why do electricity prices go negative in some markets?

Prices can fall below zero when available generation exceeds demand and the market cannot reduce supply or move it elsewhere quickly enough. Some plants continue producing because stopping and restarting is costly, while renewable output, network constraints and contractual arrangements can affect market offers. A negative price is a wholesale signal for a particular market zone and interval, not a universal value for electricity.

How can electricity have a negative wholesale price?

Wholesale market participants submit bids and offers for delivery intervals. When supply exceeds demand, a generator may accept a negative clearing price rather than incur shutdown and restart costs or depart from operating commitments. The market settlement can therefore compensate the buyer while charging the generator for that interval. Retail customers and many bilateral contracts do not automatically settle on the same basis.

What drives negative day-ahead prices in Europe?

Low demand, abundant wind or solar generation and inflexible generation can coincide, while transmission constraints may limit how much surplus power can move to another market area. The European Commission counted 4,407 negative-price hours across the selected day-ahead markets it tracked in Q2 2025. That is an aggregate across market areas, not a single set of 4,407 distinct hours on one continental clock.

Do negative electricity prices lower business bills?

Not necessarily. A negative wholesale price affects the energy settlement for a particular interval, while a business invoice also depends on its supply contract, tariff structure, network charges, taxes and other agreed services. The European Commission describes these as distinct components of electricity prices, so a short negative-price period does not automatically make the total invoice negative or reduce every billed charge. The Commission’s explanation of electricity price components provides further context.

Build a Gas Flex Offer Around Verifiable Exposure

A gas non-take right works only when the commercial trigger, physical nomination process and settlement method fit together. At Nedjma Corporation, our NOOR-Trading division supports market intelligence, commercial structuring, due diligence and execution coordination for energy opportunities. Explore how Nedjma connects international trading, energy solutions and technology capabilities to assess a structure against its market and operational constraints.

 
 
bottom of page